Date and Time Setting
Once all other settings are complete and the radio link is operational, set the Date and Time using
the Maintenance/Tools Menu.
Note: The date and time settings are lost on power down and must be re-entered on
power up. Date and time are used for log entry purposes.
Control Channel
The control channel runs from the UHF Telemetry Receiver to the UHF Telemetry Transmitter. To
activate the control, apply +5 to +36 V across the CTRL IN (+, -) inputs located on the rear of the
receiver unit at the terminal strip. These inputs are isolated from ground and power.
The control channel is deactivated when less than 5 V or open circuit is present at these inputs.
When activated, the control channel will cause a FET relay to close at the UHF Telemetry
Transmitter (RF Repeater end). This output is ground referenced. The FET relay withstands
+36 VDC when open/deactivated and will conduct up to 2 Amps of load current when
closed/activated. The output terminal is located on the terminal block below the MDS modules,
CTRL OUT with white wire attached.