164 GE MDS entraNET Reference Manual 05-4055A01, Rev. D
NOTE: Reprogramming does not work over the air when the settings
Hop Time=7, FEC=On and Encryption=On are used at the AP.
To Maximize Overall Data Performance
Change the
Buffer Size for serial ports to the maximum of 1500.
Longer packets are sent over the air, reducing overhead. On the
down side, if a packet is corrupted, it takes longer to
be retransmitted.
•Use the Packet Statistics Menu to check Packets Received by
Zone
.
Counts should be evenly distributed across all zones. Block the
zones at the AP that have poor performance. (Main Menu > Radio
Configuration > Skip Zone Option)
•Use the Packet Statistics Menu to check for errors, retries and
dropped packets. Do the same with Ethernet traffic.
Note that with weak signals, interference, or hidden nodes, the
optimal performance may be lower due to collisions and retries.