Microwave Data Systems MDS entraNET 2400 Especificaciones Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 220
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
05-4055A01, Rev. D GE MDS entraNET Reference Manual 11
1.4.1 Intrusion Detection via SNMP Traps
In addition to the operative tools and techniques, the entraNET system
provides an SNMP-based network management system with traps
(alarms) that report suspicious activities or events. These include:
Log-in attempt limit exceeded (accessed via HTTP)
Successful log-in or logout (accessed via HTTP)
Airsnort and other war-driving intruders in
parking lots, near buildings, etc.
9Frequency-hopping spread
spectrum (FHSS) does not talk
over the air with standard 802.11b
cards
9The transceiver cannot be put in a
“promiscuous” mode
9Proprietary data framing
Eavesdropping, intercepting messages
9128-bit encryption
Key cracking
9Automatic Key Rotation algorithm.
In addition, a Force Key Rotation
command is available to
immediately rotate the keys of the
AP and synchronize all Remotes
with it.
Replaying messages
9128-bit encryption with rotating
keys
Unprotected access to configuration via
SNMP
9Non-secure SNMP versions can be
enabled or disabled at will.
9SNMPv3 password protection
Potential, ongoing attacks
9Provides early warning via SNMP
through critical event reports of
unauthorized log-in attempts and
suspicious activities
Table 1-2. Security Risk Management
Security Risk The GE MDS entraNET Solution
Vista de pagina 20