Microwave Data Systems MDS entraNET 2400 Especificaciones Pagina 201

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 220
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 200
05-4055A01, Rev. D GE MDS entraNET Reference Manual 191
TRANSCEIVER MANAGEMENT
Methods Supported (AP): • HTTP (embedded Web server)—pending
• Telnet
• Local console via COM1 port
• SNMPv1/2/3. MIB II, Enterprise MIB—pending
• SYSLOG
• GE MDS NETview MS
TM
—pending
Methods Supported (Remote): Local console via COM1 port
ENVIRONMENTAL
Temperature Range: -40C to +70C (-33.8F to +158F)
Humidity: 95% at +40° C (104° F); non-condensing
Input Power: 6.0*–30 Vdc (13.8 Vdc nominal)
*Measured at the radio connector, not the source
Power Consumption: 7.05 Watts maximum at 1 Watt RF output
(See below for details by model and voltage)
Transmit: 900 MHz AP:
1175 mA at 6 Vdc
525 mA at 13.8 Vdc
270 mA at 30 Vdc
900 MHz Remote:
1025 mA at 6 Vdc
600 mA at 13.8 Vdc
240 mA at 30 Vdc
2400 MHz AP:
1091.7 mA at 6 Vdc
488.5 mA at 13.8 Vdc
253.3 mA at 30 Vdc
2400 MHz Remote:
941.7 mA at 6 Vdc
433.8 mA at 13.8 Vdc
223.3 mA at 30 Vdc
Receive: 900 MHz AP:
510 mA at 6 Vdc
220 mA at 13.8 Vdc
115 mA at 30 Vdc
900 MHz Remote:
260 mA at 6 Vdc
120 mA at 13.8 Vdc
65 mA at 30 Vdc
2400 MHz AP:
533.3 mA at 6 Vdc
230.1 mA at 13.8 Vdc
119.7 mA at 30 Vdc
2400 MHz Remote:
283.3 mA at 30 Vdc
130.1 mA at 13.8 Vdc
69.7 mA at 30 Vdc
Sleep (all remotes): 130 mA at 6 Vdc
15 mA at 12 Vdc
8 mA at 30 Vdc
Vista de pagina 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 219 220

Comentarios a estos manuales

Sin comentarios