Microwave Data Systems MDS entraNET 2400 Especificaciones

Busca en linea o descarga Especificaciones para Redes Microwave Data Systems MDS entraNET 2400. Microwave Data Systems MDS entraNET 2400 Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 148
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
System Guide
Extended Range
IP Networking Transceivers
MDS entraNET
Microwave Data Systems Inc.
Access Point
Serial Remote
Ethernet Remote
MDS 05-4055A01, Rev. A
OCTOBER 2003
Vista de pagina 0
1 2 3 4 5 6 ... 147 148

Indice de contenidos

Pagina 1 - MDS entraNET

System GuideExtended RangeIP Networking TransceiversMDS entraNET Microwave Data Systems Inc. Access PointSerial RemoteEthernet Remote MDS 05-4055A01

Pagina 2

2 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 3 - Contents

92 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AVER[VER, SWID1=, SREV1=, XSREV1=, SWID2=, SREV2=, XSREV2=, IMAGE=<im-age>, RADIOSW=, H2H=

Pagina 4

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 934.2 UPGRADING REMOTE FIRMWAREA Remote radio’s firmware may be upgraded using the Windows-based

Pagina 5

94 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A• Perform Upgrade—Click this button to begin the upgrade process.• Status—Shows the action bein

Pagina 6

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 955SAMPLE CONFIGURATIONS5 Chapter Counter Reset ParagraphContents5.1 INTRODUCTION ...

Pagina 7 - RF Exposure

96 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 8

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 975.1 INTRODUCTIONThis chapter provides details of how radios should be configured and connected

Pagina 9 - INTRODUCING THE

98 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A5.1.2 IP-to-Remote Serial Application ExampleThis configuration makes any data sent or received

Pagina 10

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 995.1.3 Point-to-Point, Serial-to-Serial Application ExampleOnce the transceivers are configured

Pagina 11 - 1.1 PRODUCT DESCRIPTION

100 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A5.1.4 Point-to-Multipoint Serial-to-Serial Application ExampleThe operation and data flow for

Pagina 12

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1015.1.5 Mixed Mode Application ExampleIn this configuration, the Host PC can use both TCP and Se

Pagina 13 - 1.2 APPLICATIONS

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 3 1.1 PRODUCT DESCRIPTION This manual presents installation and operating instructions for the M

Pagina 14

102 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ATable 5-6. Serial Port Application Configuration MDS entraNET 900Unit LocationMenu Item Setti

Pagina 15 - Serial Interfaces

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1036INSTALLATION6 Chapter Counter Reset ParagraphContents6.1 INSTALLATION ...

Pagina 16

104 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 17 - 1.4 ACCESSORIES

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1056.1 INSTALLATIONThis section provides tips for selecting an appropriate site, choosing an ante

Pagina 18 - Table 1-3. Accessories

106 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AInvisible place holderFigure 6-3. Mounting Brackets Spacing—Remote6.1.2 Site SelectionSuitable

Pagina 19 - EVALUATION

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 107– 90 dBm provide a “fade margin” of 15 dB to account for variations in signal strength that ma

Pagina 20

108 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AInvisible place holderFigure 6-5. Typical Yagi Antenna (mounted to mast)FeedlinesThe choice of

Pagina 21 - 2.1 INTRODUCTION

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 109Table 6-2 outlines the minimum lengths of RG-214 coaxial cable that must be used with common M

Pagina 22

110 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AIn general, keep the following points in mind when setting up your com-munications network.1.

Pagina 23 - ANTENNA PORTS

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1116.1.7 How Much Output Power Can be Used?The transceiver is normally supplied from the factory

Pagina 24 - Wire Ports

4 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A apply power, set a few operating parameters and you are done. No license is required for opera

Pagina 25 - (See Text)

112 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A* Most antenna manufacturers rate antenna gain in dBd in their litera-ture. To convert to dBi

Pagina 26 - COM1 port

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1136.2 dBm-WATTS-VOLTS CONVERSION CHARTTable 6-4 is provided as a convenience for determining the

Pagina 27 - COM1 Port

114 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 28 - OPERATION

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1157TROUBLESHOOTING &RADIO TESTS7 Chapter Counter Reset Paragraph7.1 TROUBLESHOOTING...

Pagina 29 - 2.6.1 Verifying Connectivity

116 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 30 - Figure 2-8. Ping Test Setup

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1177.1 TROUBLESHOOTINGSuccessful troubleshooting of a wireless system is not difficult, but requi

Pagina 31 - AP MANAGEMENT

118 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. Aresolving common system difficulties using the LEDs, and Table 7-3 other simple techniques. Ta

Pagina 32

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 119good source of information that may be used remotely to provide pre-liminary diagnostic inform

Pagina 33 - 3.1 INTRODUCTION

120 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AThe following is a summary of how several screens in the entraNET Management System can be use

Pagina 34

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 121pected. Blocking these zones may eliminate or reduce harmful interference. (See “Skip Zone Opt

Pagina 35

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 5 • Low Power Consumption—Sleep and Shutdown modes to enable solar-powered operation• Single Rad

Pagina 36 - (Telnet Similar)

122 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AThese various events are stored in the transceiver’s “Event Log” and can be a valuable aid in

Pagina 37 - COM1 port via a serial cable

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 123RSSI accurately reflects any change in the link signal strength. The higher the indication (les

Pagina 38

124 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 39 - 3.1.4 Navigating the Menus

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1258TECHNICAL REFERENCE8 Chapter Counter Reset ParagraphContents8.1 DATA INTERFACE CONNECTORS..

Pagina 40 - 3.2 BASIC DEVICE INFORMATION

126 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 41 - 3.2.2 Main Menu

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1278.1 DATA INTERFACE CONNECTORSThree types of data interface connectors are used on entraNET tra

Pagina 42 - PARAMETERS

128 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A8.1.2 COM1 Port (AP, Remotes)A PC may be connected to the Remote transceiver’s COM1 port (RJ-1

Pagina 43 - From Access Point

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1298.2 TECHNICAL SPECIFICATIONSGENERALTemperature Range: –40° C to +70° C (–40° F to 158° F)Humid

Pagina 44 - 3.3.2 IP Configuration Menu

130 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ARemote Radios: • Command line via COM1 portDATA CHARACTERISTICSPORTS (AP):Ethernet:Interface C

Pagina 45 - (User Review Required)—ID of

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 131Occupied Bandwidth: 200 kHzRECEIVER:Type: Double conversion superheterodyneSensitivity: –105 d

Pagina 46

6 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. Amore associated Remote units, as shown in Figure 1-2 on Page 6. A LAN provides communications b

Pagina 47

132 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 48 - 3.4 CONFIGURING RADIO

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1339DEFINITIONS OF TERMS9 Chapter Counter Reset Paragraph10 Chapter Counter Reset ParagraphIf you

Pagina 49 - Figure 3-13. Skip Zones Menu

134 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AdBm—Decibels referenced to one milliwatt. An absolute unit used to measure signal power, as in

Pagina 50 - INTERFACES

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 135movement or changing atmospheric losses. A fade margin of 15 to 20 dB is usually sufficient in

Pagina 51 - Serial Data Port

136 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. Apose of gathering telemetry data. Figure 1-2 on Page 6 shows an example of an MAS system.MCU—M

Pagina 52

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 137connected to an access point can be turned off, moved to another place, turned back on, and wh

Pagina 53 - (IP-to-Serial Example)

138 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ASTP—Spanning Tree ProtocolStanding-Wave Ratio—See SWR.SWR—Standing-Wave Ratio. A parameter rel

Pagina 54 - COM port in

IN CASE OF DIFFICULTY...MDS products are designed for long life and trouble-free operation. However, this equipment, as with all electronic equipment,

Pagina 55

Microwave Data Systems Inc.Rochester, NY 14620General Business: +1 585 242-9600FAX: +1 585 242-9620Web: www.microwavedata.com175 Science ParkwayA prod

Pagina 56

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 7pendent and the transceiver provides seamless simultaneous operation as shown in Figure 1-3. Inv

Pagina 57 - 3.6 SECURITY CONFIGURATION

8 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. Afor EIA-232 signaling. The COM2 port supports standard EIA-232 sig-naling and acts as a data-com

Pagina 58

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 91.3.1 Intrusion Detection via SNMP Traps(Available soon)In addition to the operative tools and t

Pagina 59 - 3.7 WIRELESS NETWORK MENU

10 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ATable 1-3. AccessoriesAccessory Description MDS Part No.AC Power Adapter KitA small power suppl

Pagina 60

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 112 TEST SETUP AND EVALUATION2 Chapter Counter Reset ParagraphContents2.1 INTRODUCTION ...

Pagina 62 - Figure 3-26. Remote Database

12 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 63

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 132.1 INTRODUCTIONPrior to field installation, it is recommended that the radio system be set up

Pagina 64 - 3.8 STATISTICS/EVENT LOG

14 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AInvisible place holderFigure 2-1. Access Point Interface ConnectorsFigure 2-2 shows the interfa

Pagina 65

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 15Invisible place holderFigure 2-3. Serial Remote Interface Connectors2.2 STEP 1—CONNECT THE ANTE

Pagina 66

16 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ANOTE: It is very important to use attenuation between all units in thetest setup. The amount of

Pagina 67

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 172.4 STEP 3—CONFIGURE THE TRANSCEIVERS2.4.1 Access Point ConfigurationThe Access Point must be c

Pagina 68 - Ethernet Packet

18 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A5. Repeat Steps 1–4 for any other AP units in your radio system.NOTE: The Management System sup

Pagina 69 - 3.8.5 Event Log Menu

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 19Invisible place holderFigure 2-7. Remote Configuration SetupLog inFollow these steps to login t

Pagina 70 - Figure 3-34. Event Log Menu

20 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AThis concludes the basic setup of a Remote radio. A full listing of Remote programming commands

Pagina 71 - (Telnet/Terminal only)—IP

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 21• LAN/ETH (Ethernet units)—On or blinks intermittently • COM2—Blinks to indicate data communica

Pagina 72 - 3.9 DEVICE INFORMATION MENU

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide i Contents 1 INTRODUCING THE entraNET SYSTEM ... 1 1.1 PRODUCT DESCRIPTION...

Pagina 73 - 3.10 MAINTENANCE/TOOLS

22 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AInvisible place holderFigure 2-8. Ping Test Setup(To test connectivity between an AP and an Eth

Pagina 74 - 3.10.1Reprogramming Menu

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 233AP MANAGEMENT3 Chapter Counter Reset Paragraph3.1 INTRODUCTION ...

Pagina 75

24 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ARemote Management Menu...52Remote Databa

Pagina 76 - Firmware

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 253.1 INTRODUCTION The MDS entraNET 900 AP is equipped with an embedded manage-ment system that i

Pagina 77 - LAN, or Terminal emulator

26 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AInvisible place holder• Spacebar used to make some menu selections• Bolded items indicate a men

Pagina 78

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 27Invisible place holder• Spacebar used to make some menu selections• Bolded items indicate a men

Pagina 79

28 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A3.1.2 Differences in the User InterfacesThere are slight differences in navigation between Teln

Pagina 80

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 293.1.3 Accessing the Embedded Management SystemThe menu-based management system provides access

Pagina 81

30 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AProcedure with Terminal Emulatora. Connect a computer’s serial communications port to the trans

Pagina 82

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 31d. A login screen will be displayed that requires a user name and password to access the Manage

Pagina 83

ii MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AEthernet Remotes...

Pagina 84

32 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A3.1.5 Logging Out of the entraNET Management SystemNOTE: To maintain security, it is best to fo

Pagina 85 - 3.10.3 Ping Utility Menu

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 33played, an “A)” will appear to the left of the Device Status field as seen in Figure 3-6. Press

Pagina 86 - 3.10.4Authorization Keys Menu

34 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A• Local Serial Configuration—Tools to configure the COM1 and COM2 serial port of the AP. (See “

Pagina 87 - REMOTE RADIO

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 35Invisible place holderFigure 3-8. Network Configuration MenuFrom Access PointThis menu is subdi

Pagina 88

36 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A3.3.2 IP Configuration MenuFigure 3-9. IP Configuration Menu• IP Address (User Review Recommend

Pagina 89 - 4.1 INTRODUCTION

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 373.3.3 Wireless MAC Configuration• Radio Net(work) Address (User Review Required)—ID of the net

Pagina 90 - COMMAND DESCRIPTION

38 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A• BSP Routing Enable—This parameter enables intra-cell and routing of Basic Serial Protocol pac

Pagina 91

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 39• SNMP v3 Priv Password—Privacy password stored in flash memory. Used when the SNMP Agent is ma

Pagina 92

40 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A• Bridge Forward Delay—This value decides how long a bridge will spend in the “learning” and “l

Pagina 93

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 41• Broadcast Repeat Count—Sets the number of times point-to-multipoint messages will be transmit

Pagina 94

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide iiiRemote Database Menu...

Pagina 95

42 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A3.5 CONFIGURING THE SERIAL INTERFACES3.5.1 OverviewTo understand the operation of the radio sys

Pagina 96

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 43To configure IP-to-remote serial services, use the Remote Serial Gateway menu (Figure 3-20 on P

Pagina 97

44 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A3.5.2 Serial Data Port Configuration Menu(Local Serial-to-Remote Serial, or IP-to-Local Serial)

Pagina 98

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 45The Serial Configuration Wizard consists of a series of screens used to set all of the paramete

Pagina 99

46 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AThe following text explains the key settings for the serial configuration menus.• Port Status—E

Pagina 100

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 47• Inter-Packet Delay— Number of characters that rep-resent the end of a message (inter-characte

Pagina 101 - 4.2 UPGRADING REMOTE FIRMWARE

48 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. Ahost) the RSG will revert to its configured IP address and port for upstream data destined for

Pagina 102

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 493.6 SECURITY CONFIGURATIONThere are many options for assisting you in providing secondary secu-

Pagina 103 - CONFIGURATIONS

50 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A• HTTP Access—Prevents remote access through HTTP (Web browser) on Port 80 [Enabled/Disabled; D

Pagina 104

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 51 Figure 3-22. Approved Remotes List Menu• Add Remote—Enter the serial number of Remote.[ten-dig

Pagina 105 - Connection

iv MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A5.1.4 Point-to-Multipoint Serial-to-Serial Application Example ...

Pagina 106 - Invisible place holder

52 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. Awhich is related to Remotes, is not actually sent to Remotes, but is stored in a local database

Pagina 107 - RemoteAccess Point

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 53Figure 3-24. Remote Management MenuWhen “Manage Selected Remote” is chosen, the screen shown in

Pagina 108 - COM port

54 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A• Serial Configuration—Tool for configuring COM1/2 parameters, including: Port Mode, Baud Rate,

Pagina 109 - Access Point

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 55• RX Pkts—Number of packets received from this Remote.• Num EPs—Number of endpoints connected t

Pagina 110

56 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A• RxPkts—Over-the-air data packets received by the transceiver. and passed on to the endpoint d

Pagina 111 - INSTALLATION

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 57Invisible place holderFigure 3-29. Statistics/Event Log Menu (Main Screen)• COM1/2 Serial Data

Pagina 112

58 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A3.8.1 COM1 & 2 Serial Data Statistics Menus(See Figure 3-30)Invisible place holderFigure 3-

Pagina 113 - 6.1 INSTALLATION

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 59Figure 3-31. Serial Data Statistics Screen (Verify as latest screen)(Both COM1 and COM2 are sho

Pagina 114 - 6.1.2 Site Selection

60 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AFigure 3-32. Sample Packet Statistics Menu (Ethernet shown)Wireless Packet Statistics• Packets

Pagina 115 - Unity-gain Type

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 613.8.4 Radio Packet StatisticsThe previous screen dealt with Ethernet-related information. The R

Pagina 116

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide v Copyright Notice This publication is protected by U.S.A. copyright law. Copyright 2003, Microw

Pagina 117

62 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. Aevents. These will cause the unit to enter an “alarmed” state and the POWER LED to blink until

Pagina 118

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 63Invisible place holderFigure 3-35. View Event Log Menu• Clear Log—Purges the log of all stored

Pagina 119

64 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A3.9 DEVICE INFORMATION MENUFigure 3-36 is the menu/screen that displays basic administrative da

Pagina 120 - CHART, on Page 113

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 65Device Names MenuFigure 3-37. Device Names Menu• Device Name—Device Name, used by the transceiv

Pagina 121

66 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AFigure 3-38. Maintenance/Tools Menu3.10.1Reprogramming MenuThe AP transceiver has two copies of

Pagina 122

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 67• Firmware Filename—Name of file to be received from the TFTP server.[Any 40-character alphanum

Pagina 123 - RADIO TESTS

68 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A• Web Browser—Connect to the transceiver using a Web browser on a local PC connected directly t

Pagina 124

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 69Invisible place holderFigure 3-41. Upgrade Configuration—Option 2(TFTP Server and Firmware File

Pagina 125 - 7.1 TROUBLESHOOTING

70 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A5. Pull the firmware file through the TFTP server into the entraNET unit.(Main Menu>Maintenanc

Pagina 126 - Management System

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 71• TFTP Timeout—Time in seconds the TFTP server will wait for a packet ACK (acknowledgment) from

Pagina 127

vi MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A The transceiver has been recognized for use in these hazardous locations by two independent a

Pagina 128

72 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. Ato appear below associated parameter lines. Some of the values used in the calibration of the u

Pagina 129

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 73The contact person regarding this unit.Description: Link to Campus ServerA brief general descri

Pagina 130 - LINK LED

74 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ASkipped Hop Zone4: ActiveSkipped Hop Zone5: ActiveSkipped Hop Zone6: ActiveSkipped Hop Zone7: A

Pagina 131 - Statistics)

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 75Com1 Serial Data Mode: UDPIP Protocol for COM1 data modeCom1 Serial Data Baud Rate: 9600Baud ra

Pagina 132

76 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ASNMP Enable: disabledEnable/Disable SNMP AgentApproved Remotes List Enable: disabledSetting to

Pagina 133 - TECHNICAL REFERENCE

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 77• Change only the parameter values.• Capitalization counts in some field parameters. (Example:

Pagina 134

78 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A3.10.4Authorization Keys MenuFigure 3-44. Authorization Keys Menu• Authorization Key—Initiate t

Pagina 135 - 8.1 DATA INTERFACE CONNECTORS

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 794REMOTE RADIOMANAGEMENT4 Chapter Counter Reset ParagraphContents4.1 INTRODUCTION 814.1.1 Pr

Pagina 136 - 8.1.2 COM1 Port (AP, Remotes)

80 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ALANCOM1COM2PWRLINK

Pagina 137 - 8.2 TECHNICAL SPECIFICATIONS

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 814.1 INTRODUCTIONThe configuration of Remote transceivers is performed through a PC terminal con

Pagina 138 - RADIO CHARACTERISTICS

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 1 1 INTRODUCING THE entraNET SYSTEM 1 Chapter Counter Reset Paragraph Contents 1.1 PRODUCT DES

Pagina 139

82 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ACommand ResponsesThe transceiver supports two command response formats—standard (plain language

Pagina 140

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 834.1.4 Detailed Command DescriptionsHELP Lists commands supported for the current user login lev

Pagina 141 - DEFINITIONS OF TERMS

84 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AAPx= —AP units, where x = 1 to 10. Sets / displays the serial number for one of 10 approved APs

Pagina 142 - COM1 and COM2 Port of the

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 85FORMAT=<format>—Sets / displays data characters, parity, and stop bits setting of the COM

Pagina 143

86 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A7E2—7 char bits, even parity, 2 stop bits8N1—8 char bits, no parity, 1 stop bit (Default)8N2—8

Pagina 144

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 87OWNER=<owner>—Sets/displays owner information string. Owner can program any information (

Pagina 145

88 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. AENCRYPT[MODE=<mode>, PHRASE=<phrase>, CMD=<cmd>]This command sets / displays

Pagina 146

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 89HELP Lists commands supported for the current user login level.LOG[CLEAR, SHOW, TOTAL=, CMD=<

Pagina 147 - IN CASE OF DIFFICULTY

90 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. ARADIO[UNIT=<unit>, NETADDR=<netaddr>, PWR=<pwr>, SYNC=, RSSI=, CONN=<conn&

Pagina 148

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 91cases where power consumption must be kept to a minimum, such as in solar-powered installations

Comentarios a estos manuales

Sin comentarios