MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 99
5.1.3 Point-to-Point, Serial-to-Serial Application
Example
Once the transceivers are configured and the changes have been exe-
cuted, they begin processing any data presented at the
COM ports. Data
presented at the Access Point’s
COM port is packetized and sent over the
air via a proprietary protocol to the Remote. Upon receiving the packet,
the Remote sends the data out its
COM port. Likewise, data presented at
the Remote’s
COM port is packetized, sent to the Access Point, stripped,
and sent out the Access Point’s
COM port. Note that this configuration
does not use multicast addressing.
Invisible place holder
Figure 5-3. Point-to-Point Serial-to-Serial Application Diagram
Table 5-3. IP-to-Remote Serial Application Configuration.
MDS entraNET 900 Unit
Location
Menu Item Setting
Access Point (COM2) Remote ID 1155883
COM Port COM2
Mode TCP Server
Radio IP Port 30066
Remote Unit (COM2) Mode COM2 in transparent data mode
Baud 19200
Format 8N1
Buffer 256
DelayChars 4
Seamless TX data only
EIA-232
Terminal
or Computer
192.168.0.10
RTU
EIA-232
192.168.0.1
C
O
M
2
P
W
R
L
I
N
K
C
O
M
1
RemoteAccess Point
L
A
N
C
O
M
1
C
O
M
2
P
W
R
L
I
N
K
Table 5-4. Point-to-Point Serial-to-Serial Configuration
MDS entraNET 900
Unit Location
Menu Item Setting
Access Point (COM2) Port Status Enabled
Mode Serial-to-Serial
Remote UnitID 1155999 (example)
Rem. COM Port COM2
Baud Rate 19200
Byte Format 8N1