MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 17
2.4 STEP 3CONFIGURE THE
TRANSCEIVERS
2.4.1 Access Point Configuration
The Access Point must be configured first, as Remote transceivers
depend on the AP’s beacon signal to achieve a “connected” (linked)
state. To configure the Access Point, connect a PC with the radio’s
COM1 port and establish a terminal session (i.e., HyperTerminal) using
the following data parameters: 19200 bps, 8 bits, no parity, one stop bit
(8N1), flow control disabled, VT100 emulation.
Alternatively, you can connect a PC’s Ethernet port to the AP’s
LAN port
using an Ethernet crossover cable. Note: This method requires that the
radio have a valid IP address programmed—it will not contain an appro-
priate IP address as shipped from the factory.
Figure 2-6 shows the basic setup for configuring an AP with a personal
computer.
Invisible place holder
Figure 2-6. AP Configuration Setup
Log In
Log into the AP as follows:
1. Press the key to receive the
login prompt. The COM1/LAN
LED flashes to indicate data communications.
2. At the
login prompt, enter the username (admin is the default user-
name). Press .
3. At the Password prompt, enter the password. (admin is the default
password). Press . The Starting Information Screen appears.
4. Review the current settings and make any necessary changes. Refer
to AP Configuration Settings, on Page 18 for configuration guid-
ance.
PC Running Terminal Session
(19,2000 bps, 8N1)
Access Point
COM1 or LAN Port