82 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A
Command Responses
The transceiver supports two command response formats—standard
(plain language) and a hex format that may be copied into a configura-
tion script. If you enter 0 after a command, the command executes nor-
mally (plain language). If you enter 1 after the command, the response
is reported in hex format. Hex format is useful for automated processing
of response data.
4.1.3 Minimum Remote Configuration
Remote radios require little configuration to operate, as most of the con-
figuration is executed at the AP. The minimum set of parameters that
need to be set at a Remote are as follows:
RADIO NETADDR—Radio’s Network Address. Must match AP’s address.
RADIO UNIT—32-bit unit address. Defaults to radio’s serial number, but
is user programmable.
RADIO PWR—RF output power setting. Value is in dB, with range of 20
(0.1 watt) to 30 (1 watt).
Table 4-1. Remote CommandsQuick Reference
COMMAND DESCRIPTION
ALARM
Display current alarm conditions by class
APLIST
Set/display serial numbers of up to 10 APs with which the Remote
should accept registration
AUTH
Set/display the authorization key and a list of authorized features
COM1
Set/display the conguration of COM1 port (baud rate, data format,
buffer size, inter-packet gap)
COM2
Set/display the conguration of COM1 port (baud rate, data format,
buffer size, inter-packet gap)
CONFIG
Shows the dump conguration of all settable parameters
DEVICE
Set/display device conguration. Here, items such as Owner, Com-
pany, and Serial Number may be found.
DIRECT
Set/display the conguration for direct mode operation
ENCRYPT
Set/display the conguration for data encryption
ETH
Set/display the conguration of the Ethernet port
HANDOFF
Set/display the conguration of hand-off capability
HELP
Lists commands supported for the level of the logged in user
LOG
Set/display the event log information
LOGIN
Secure login. Prompts user for case sensitive username and pass-
word
LOGOUT
Logs user off and ends terminal session
PASSWORD
Sets the user login password for user at current access level or less
Vista de pagina 89