90 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A
RADIO
[UNIT=<unit>, NETADDR=<netaddr>, PWR=<pwr>, SYNC=, RSSI=,
CONN=<conn>, AP=, REFRESH=<refresh>, CMD=<cmd>]
This command sets / displays the radio configuration and status.
Optional Arguments:
UNIT=<unit>—32-bit user-programmable unit address. Defaults to serial
number but is user programmable.
NETADDR=<netaddr>—Current Radio Network Address. Acceptable
value range is 0–32637
PWR=<pwr>—Current Radio Power Setting. Value is in dBm with an
acceptable range of 20–30.
SYNC= Read only. Shows current state of radio synchronization.
RSSI= Read only. Shows Received Signal Strength (RSSI). Value is
shown in dBm with a range of -120 to 0. This value is refreshed every
three seconds.
CONN=<conn>—Determines whether the device (Remote) has associated
with an Access Point.
NOT ASSOCIATED: Remote radio not associated with an AP
ASSOCIATED: Remote radio associated with an AP
AP= Read only. Shows associated AP’s Serial Number. Acceptable
value range is 1–99999999
REFRESH=<refresh>—Read only. Connection refresh period in seconds
with an acceptable value range of 0–255
REBOOT
[REBOOT, SAME, OTHER, APP1, APP2]
This command is used to reboot the radio's firmware.
Optional Arguments:
SAME—Same Image
OTHER—Other Image
APP1—Application Image 1
APP2—Application Image 2
SLEEP
[SLEEP, MODE=<mode>, WAKE=<wake>, DTRSENSE=<dtrsense>, PERIOD=<pe-
riod>, HANGTIME=<hangtime>, CMD=<cmd>]
This command sets/displays one of the low power operating modes the
Remote radio will operate under. These modes are commonly used in
Comentarios a estos manuales