Microwave Data Systems MDS entraNET 2400 Especificaciones Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 148
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 19
Invisible place holder
Figure 2-7. Remote Configuration Setup
Log in
Follow these steps to login to the radio.
1. Press a few keystrokes to receive the
entranet> prompt. (The
COM1/ETH LED blinks to indicate data communication.)
2. At the
entranet> prompt, type login. Press .
3. At the next prompt, enter username (default username is admin).
Press .
4. At next prompt, enter Password (default password is admin). Press
. The unit is now ready to accept commands.
Set/Verify Network Address
The only setting normally required for initial checkout of a Remote
radio is the Network Address. All radios in a given network must be pro-
grammed with the same network address as the AP or communication
will not be possible. Follow the steps below to check the address, and
program a new one if necessary.
1. Enter the
RADIO NETADDR command. This displays the radio’s
currently programmed network address.
2. If changes are required, enter the
RADIO NETADDR= <netaddr> com-
mand, where
<netaddr> is a number from 1 to 20000. (The network
address of the Remote radio must match that of the AP.)
3. Verify that the
LINK LED lights to indicate successful connection
with the AP. (It may take several seconds for the LED to light).
4. Repeat Steps 1–3 for each Remote radio to be installed in the net-
work.
PC Running Terminal Session
(19,2000 bps, 8N1)
L
I
N
K
C
O
M
2
C
O
M
1
P
W
R
Remote
COM1 Port
ENTER
ENTER
ENTER
ENTER
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 147 148

Comentarios a estos manuales