MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 87
OWNER=<owner>—Sets/displays owner information string. Owner can
program any information (as one continuous string). Allowable length
is 1–30 characters.
UPTIME= —Read Only. Displays current system uptime <YY-MM-DD
hh:mm:ss>. Allowable length is 1–11 characters.
SER=— Read Only. Sets / displays device serial number. Acceptable
value range is 1–99999999
XSNUM= —Read Only. Sets / displays Radio Board Serial Number.
Acceptable value range is 0–99999999.
DIRECT
[DEFAULT=<default>, MODE=<mode>, STATE=, TYPE=<type>, NETADDR=<ne-
taddr>, CMD=<cmd>]
Sets / displays the configuration for direct mode operation (Remote to
Remote).
Optional Arguments:
DEFAULT=<default>—Sets / displays default DIRECT mode.
OFF: Direct Mode defaults to disabled
ON: Direct Mode defaults to enabled
EXT: Direct Mode defaults to control via external signal
MODE=<mode>—Sets / displays DIRECT mode setting
OFF: Direct Mode disabled
ON: Direct Mode enabled
EXT: Direct Mode controlled via external signal
STATE=— Read Only. Display status of DIRECT mode setting.
OFF: Direct mode state: off
ON: Direct mode state: on
TYPE=<type> Read / Write. Sets / displays whether device acts as root or
node when in direct mode.
NODE: Direct type is Node
ROOT: Direct type is Root
NETADDR=<netaddr>—Sets / display Network (system) address when in
direct mode. Acceptable value range is 0–32637.
CMD=<cmd>—If set to 0, the command executes normally. If <cmd> is
set to 1, the command reports all settings in a format that may be copied
into a configuration script.