72 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A
to appear below associated parameter lines. Some of the values used in
the calibration of the unit’s built-in test equipment have been deleted to
reduce space. This presentation is offered as a guide to the type of infor-
mation contained in the file. See “Editing Configuration Files” on
Page 76 for further information.
NOTE: The parameter names and the data values from the Exported
Configuration File are shown in bolded text. Any description
will be found below in an indented paragraph. Descriptions for
parameters that are functionally identical to both COM1 &
COM2 are not repeated.
Beginning of Configuration File:
; MDS entraNET
; Created 01-03-2003 6:59:41
IP Address: 192.168.1.1
The IPv4 address of this unit. This field is unnecessary if DHCP is
enabled.
NOTE: Changing the IP value via the network will cause a loss of
communication with other devices unaware of the new
address.
IP Netmask: 255.255.255.0
The IPv4 local subnet mask. This field is unnecessary if DHCP is
enabled.
IP Gateway: 0.0.0.0
The IPv4 address of the network gateway device, typically a router.
This field is unnecessary if DHCP is enabled.
Ethernet Address: 00:06:3D:00:00:5D
The physical Ethernet MAC (Media Access Controller) address of
the device. This value is set by the factory and cannot be changed.
Model Number: 900
The model number of this unit. This value is set by the factory and
cannot be changed.
Serial Number: 1026295
The serial number of this unit. This value is set by the factory and
cannot be changed.
Unit Name: Library Admin Office
A name for this unit. It appears at the top of every menu screen.
Owner: Hilltop College MIS
The name of the owner of this unit.
Contact: John Galt X232
Comentarios a estos manuales