92 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A
VER
[VER, SWID1=, SREV1=, XSREV1=, SWID2=, SREV2=, XSREV2=, IMAGE=<im-
age>, RADIOSW=, H2H=, CONFIG=, EVENT=, LOG=, HREV=, XHREV=,
CMD=<cmd>]
This command sets/displays the current Version information for the
radio.
Optional Arguments:
SWID1=—Shows current Software ID text (06-nnnnAnn). Allowable
length is 1–10 characters.
SREV1=—Shows software version number (xx.yy.zz). Allowable length
is 1–8 characters.
XSREV1= —Displays radio software version. Allowable length is 1–8
characters.
SWID2= —Shows current Software ID text (06-nnnnAn). Allowable
length is 1–10 characters.
SREV2=—Shows software version number (xx.yy.zz). Allowable length
is 1–8 characters.
XSREV2= —Displays radio software version. Allowable length is 1–8
characters.
IMAGE=<image>—Selects boot image index.
RESET: Go to Reset Vector
APP1: Application Image 1
APP2: Application Image 2
RADIOSW= —Shows current Radio Software Version number (xx.yy.zz).
Allowable length is 1–15 characters.
H2H= — Host-to-Host protocol version number.
CONFIG= —Configuration Table version
EVENT= —This command is used to determine whether the current Event
list properties need to be upgraded or not.
LOG= —This command is used to determine whether the current Log
format needs to be upgraded or not.
HREV= —Displays OIB Board Hardware Revision. Allowable length: is
1–8 characters.
XHREV= —Radio Board Hardware Revision. Allowable length is 1–8
characters.