MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 75
Com1 Serial Data Mode: UDP
IP Protocol for COM1 data mode
Com1 Serial Data Baud Rate: 9600
Baud rate for COM1 data mode
Com1 Serial Data Tx IP Address: 0.0.0.0
COM1 data will be sent to this IP address
Com1 Serial Data Tx IP Port: 0
COM1 data will be sent to this IP port
Com1 Serial Data Rx IP Port: 0
COM1 data will be received on this IP port
Com2 Serial Data Enable: enabled
Com2 Serial Data Mode: UDP
Com2 Serial Data Baud Rate: 9600
Com2 Serial Data Tx IP Address: 169.254.10.2
Com2 Serial Data Tx IP Port: 0
Com2 Serial Data Rx IP Port: 0
Com1 Serial Data Rx IP Address: 0.0.0.0
COM1 data will be received on this IP address
Com2 Serial Data Rx IP Address: 169.254.0.2
Com2 Serial Data Flow Control: disabled
Setting to enable hardware flow control (RTS/CTS) in COM2 data
mode
SNTP Server IP: 0.0.0.0
The IPv4 address of NTP/SNTP Time Server
Com1 Serial Data Seamless Mode: enabled
Setting to enable seamless mode for COM1 data mode
Com2 Serial Data Seamless Mode: enabled
Com1 Serial Data Delimiter Chars: 4
Minimum number of characters which will be considered a gap in
seamless mode for COM1
Com2 Serial Data Delimiter Chars: 4
Com1 Serial Data Buffer Size: 20
Number of output characters which will be buffered in seamless
mode for COM1
Com2 Serial Data Buffer Size: 20
RF Frequency Hopping Format: USA/CANADA
(Read Only) The frequency-hopping rules the radio is configured to
operate under