MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 9
1.3.1 Intrusion Detection via SNMP Traps
(Available soon)
In addition to the operative tools and techniques, future releases of the
MDS entraNET 900 will provide SNMP-based network management
systems with traps (alarms) that report suspicious activities or events.
These will include:
• Unauthorized AP serial number detected at Remote
• Unauthorized Remote serial number detected at AP
• Login attempt limit exceeded
(Accessed via: Telnet, HTTP, or local)
• Successful login/logout
(Accessed via: Telnet, HTTP, or local)
1.4 ACCESSORIES
MDS entraNET transceivers may be used with one or more of the acces-
sories listed in Table 1-3. Contact the factory for ordering details.
Denial of service, where Remote radios
could be reconfigured with bad
parameters bringing the network down.
✓ Remote login
✓ Local console login
✓ Disabled HTTP & Telnet to allow
only local management services
Airsnort and other war-driving hackers in
parking lots, etc.
✓ 900 MHz FHSS does not talk over
the air with standard 802.11b cards
✓ The transceiver cannot be put in a
“promiscuous” mode
✓ Proprietary data framing
Eavesdropping, intercepting messages
✓ 128-bit encryption
Key cracking
✓ Automatic Rotating Key algorithm
Replaying messages
✓ 128-bit encryption with rotating
keys
Unprotected access to configuration via
SNMP (available soon)
✓ Will enable/disable non-secure
SNMP versions
✓ Will password-protect SNMPv3
Potential, ongoing attacks
✓ Provides early warning via SNMP
through critical event reports
(unauthorized, logging attempts,
etc.)
Table 1-2. Security Risk Management
Security Risk The MDS entraNET 900 Solution