Microwave Data Systems MDS entraNET 2400 Especificaciones Pagina 94

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 148
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 93
86 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A
7E2—7 char bits, even parity, 2 stop bits
8N1—8 char bits, no parity, 1 stop bit (Default)
8N2—8 char bits, no parity, 2 stop bits
8O1—8 char bits, odd parity, 1 stop bit
8O2—8 char bits, odd parity, 2 stop bits
8E1—8 char bits, even parity, 1 stop bit
8E2—8 char bits, even parity, 2 stop bits
NOTE: Entry of data formats other than those listed above may cause
undesired operation.
BUFFER=<buffer>—Sets / display maximum buffer size of the COM port.
Acceptable value range is 1–1500.
DELAYCHARS=<delaychars>—Sets / displays minimum inter-packet gap
for the COM port. Acceptable value range is 1–256.
CONFIG
[SHOW, SAVE=]
Saves/Displays the current configuration. The output is in a format that
may be copied back into the command line in order to set the configura-
tion.
Optional Arguments:
SHOW—Displays the current configuration. This is a read-only response.
SAVE=—Saves the current configuration.
DEVICE
[COMPANY=, MODEL=, PROD=, SREV=, OWNER=<owner>, UPTIME=, SER=, XS-
NUM=, CMD=<cmd>]
This command sets / displays the device configuration. Items such as
Owner, Company, and Serial Number can be found here.
Optional Arguments:
COMPANY= —Read Only. Sets / displays company name. Allowable
length is 1–20 characters.
MODEL=— Read Only. Sets / displays unit model number. Allowable
length is 1–20 characters.
PROD= —Read Only. Sets / displays product name. Allowable length: is
1–20 characters.
SREV= —Read Only. Sets / displays software revision ID. Allowable
length is 1–15 characters.