62 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A
events. These will cause the unit to enter an “alarmed” state and the
POWER LED to blink until the condition is corrected. All events are
stored in the Events Log that can hold about 5000 entries
.
Time and Date
The events stored in the Event Log are time-stamped using the time and
date. The user must manually enter the date and time at the Access Point.
(See “DEVICE INFORMATION MENU” on Page 64. The manually set
time and date clock is backed up by an internal battery.
Figure 3-34. Event Log Menu
• Current Alarms (Telnet/Terminal only)—View list of root
causes that have placed the Device Status in the alarmed state.
• View Event Log (see Figure 3-35)—View a list of events
stored in the current log. Some of these events are stored in vol-
atile memory and will be erased with a loss of power.
Table 3-1. Event Classifications
Level Description/Impact
Informational Normal operating activities
Minor Does not affect unit operation
Major Degraded unit performance but still
capable of operation
Critical Prevents the unit from operating
Comentarios a estos manuales