MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide 21
• LAN/ETH (Ethernet units)—On or blinks intermittently
• COM2—Blinks to indicate data communications
Table 2-2 provides details on the LED functions for Remotes and AP
radios.
Table 2-2. Transceiver LED Functions
2.6.1 Verifying Connectivity
Ethernet Remotes
If the radio network is operating properly based on observation of the
unit’s LEDs, you can use the
PING command from the AP to verify the
link integrity between the Access Point and an endpoint-device con-
nected to the Remote radio. Figure 2-8 shows the a typical arrangement
for this test.
NOTE: To conduct a Ping test, an Ethernet-enabled device must be
connected to the Remote, and it must have a compatible IP
address. Remote radios do not have an IP address and cannot
be verified directly using this method.
LED Label Activity Indication
LAN/ETH ON LAN or endpoint detected
Blinking Data TX/RX
OFF LAN not detected
COM1
(MGT System)
Blinking Data TX/RX
OFF No data activity
COM2 Blinking Data TX/RX
OFF No data activity
PWR ON Primary power (DC) present
Blinking Unit in “Alarmed” state
OFF Primary power (DC) absent
LINK
(Access Point)
ON Lights when radio has finished
its boot cycle. Remains lit.
LINK
(Remote)
ON Connected to AP
OFF Not connected to an AP