54 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A
Serial Configuration—Tool for configuring COM1/2
parameters, including: Port Mode, Baud Rate, Byte Format,
Seamless Mode, Interpacket Delay, and Buffer Size.
Statistics—Presents packet throughput and retry data for
the selected Remote
Remote Reprogramming—Menu for sending new firm-
ware images and specifying the image that will be active upon
re-boot.
Remote Database Menu
The Remote Database Menu (Figure 3-26) shows several parameters
related to the connected Remotes. is continuously updated at a refresh
rate of approximately 8 seconds.
Invisible place holder
Figure 3-26. Remote Database
UnitID—The unit ID of the connected Remote.
Conn State—Shows whether or not the Remote is connected
with the AP.
AgeOut—Number of minutes before the entry ages out and is
removed from the table. Each AP maintains a table with the
addresses of the devices it communicates with. The AgeOut count-
down is restarted to its default setting every time a message to/from
that device is detected. If no traffic with that device occurs, and it
does not respond to a final handshake request, it then “ages out” of
the table.
An aged out Remote must reconnect before it is again included in
the table. (See “database timeout” on the Wireless Network Menu,
Figure 3-23 on Page 52.
TX Pkts—Number of packets sent to this Remote.