70 MDS entraNET 900 System Guide MDS 05-4055A01, Rev. A
5. Pull the firmware file through the TFTP server into the entraNET
unit.
(Main Menu>Maintenance Menu>Reprogramming Menu>Retrieve File)
Status messages on the transfer are posted on the PC screen.
You can cancel the transfer at any time by pressing CTRL-C.
If the transfer does not start, verify that the AP and the PC can
“ping” each other.
6. Reboot the transceiver to the new firmware image to make it active.
Main Menu>Maintenance Menu>Reprogramming Menu>Reboot Device
7. Test the transceiver for normal operation.
End of Procedure
3.10.2 Configuration Scripts Menu
Figure 3-42. Configuration Files Menu
TFTP Host Address—IP address of the computer on which
the TFTP server resides. [Any valid IP address]
Filename—Name of file containing this unit’s configuration
profile that will be transferred to the TFTP server. The configu-
ration information will be in a plain-text ASCII format.
[Any 40-character alphanumeric string] May require sub-direc-
tory, for example:
cong\entranet-cong.txt. (See “Using Config-
uration Scripts” on Page 71)
NOTE: The filename field is used in identifying the desired
incoming file and as the name of file being exported to the TFTP
server. Before exporting the unit’s configuration, you may want
to name it something that reflect the unit’s services or identifi-
cation.